Electronic projects


you are here: home page :: projects :: Sensors & control :: temperature controlled :: Heating System Thermostat

Heating System Thermostat

Controlled by indoor and outdoor temperature
Simple, high reliability design

Circuit diagram

Parts:
P1 1K Linear Potentiometer
R1 10R 1/4W Resistor
R2 1K 1/4W Resistor
R3 3K3 @ 20°C n.t.c. Thermistor (see Notes)
R4 2K2 @ 20°C n.t.c. Thermistor (see Notes)
R5 10K 1/2W Trimmer Cermet
R6 3K3 1/4W Resistor
R7,R9 4K7 1/4W Resistors
R8 470K 1/4W Resistor
R10 10K 1/4W Resistor
C1,C2 470µF 25V Electrolytic Capacitors
C3 1µF 63V Electrolytic Capacitor
D1,D2,D4 1N4002 100V 1A Diodes
D3 LED Red 3 or 5mm.
Q1 BC557 45V 100mA PNP Transistor
Q2 BC547 45V 100mA NPN Transistor
Q3 BC337 45V 800mA NPN Transistor
RL1 Relay with SPDT 2A @ 220V switch
Coil Voltage 12V. Coil resistance 200-300 Ohm
J1 Two ways output socket
SW1 SPST Mains Switch
T1 220V Primary, 12 + 12V Secondary 3VA Mains transformer
PL1 Male Mains plug & cable

Device purpose:
This circuit is intended to control a heating system or central heating plan, keeping constant indoor temperature in spite of wide range changes in the outdoor one. Two sensors are needed: one placed outdoors, in order to sense the external temperature; the other placed on the water-pipe returning from heating system circuit, short before its input to the boiler. The output from the Relay contact must be connected to the boiler's start-stop control input.
This circuit, though simple, has proven very reliable: in fact it was installed over 20 years ago at my parents' home. I know, it's a bit old: but it's still doing its job very well and without problems of any kind.

Circuit operation:
When Q1 Base to ground voltage is less than half voltage supply (set by R7 & R9), a voltage is generated across R8 and the driver transistors Q2 & Q3 switch-on the Relay. When Q1 Base to ground voltage is more than half voltage supply, caused when one of the n.t.c. Thermistors lowers its value due to an increase in temperature, no voltage appears across R8 and the Relay is off.
C3 allows a clean switching of the Relay.
P1 acts as main temperature control.

Notes:
R3 is the outdoor sensor, R4 the indoor sensor.
If you are unable to find a 3K3 Thermistor for R3 you can use a 4K7 value instead. The different value can be easily compensated by means of Trimmer R5.
R5 allows to set the heating system for outdoor temperatures ranging from about +10°C downwards. The higher R5's resistance the hotter the heating system and vice versa.
The existing boiler thermostat should be set to its maximum value and not bypassed: it is necessary for safety's sake.
This circuit can be dispensed with its differential feature and converted into a simple precision thermostat omitting R3.

author: RED Free Circuit Designs
e-mail:
web site: http://www.redcircuits.com
project categories:
folder Audio (49)
folder Power & high voltage (43)
folder Radio (23)
folder Light & LED (31)
folder Tools & measurement (40)
folder Telephone (18)
folder Automotive (10)
folder Microcontrollers (12)
folder Sensors & control (47)
folder Timers & oscillators (40)
folder Miscellaneous (26)

StumbleUpon button

Share this page
Bookmark and Share
project subcategories:
All subcategories
light controlled
temperature controlled
moisture controlled
sound controlled
other

similar projects:
Auto Heat Limiter for Soldering Iron
Fancontrol
Fridge door Alarm
Frost Alarm
On-Off Temperature Control
Temperature Monitor
Temperature-controlled Fan

recently added projects:
Doorbell for the Deaf
High Quality Intercom
Combinational Conjuring Trick
POT-PLANT POWER
Ultrasonic Dog Whistle
Quiz Circuit
LED Torch
Insect Repellant
Speaker Microphone Circuit
Magic Wand Conjuring Trick.

most popular projects:
Led display digital Voltmeter
500W low cost 12V to 220V inverter
Low pass filter - Subwoofer
High And Low Voltage Cut Off With Time Delay
Metal Detector
2N3055 Power Amplifier
Basic UPS Power Supply
200W audio amplifier
LED Torch
100W RMS Amplifier


DIY Electronics Projects

Promote Your Page Too